Hardware options installation 20

Hardware options installation

Introduction

If more than one option is being installed, read the installation instructions for all the hardware options and
identify similar steps to streamline the installation process.

WARNING:

To reduce the risk of personal injury from hot surfaces, allow the drives and the

internal system components to cool before touching them.

CAUTION:

To prevent damage to electrical components, properly ground the server before

beginning any installation procedure. Improper grounding can cause electrostatic discharge.

Hard drive option

The HP ProLiant BL280c G6 Server Blade supports midline SATA hard drives and 9.5-mm SATA hard drives.
SAS hard drives are supported when the HP Smart Array P712m Controller option is installed. The HP Smart

Array P712m Controller option does not support hard drive activity LEDs when installed in the HP ProLiant

BL280c G6 Server Blade.
For information on supported hard drive options and controller options, see the server blade QuickSpecs on
the HP website (

http://www.hp.com

).

CAUTION:

Failure to follow the hard drive installation guidelines can cause hardware damage.

Always observe the installation guidelines:

Always install a spacer when installing a 9.5-mm SATA hard drive.

Be sure to use the proper screws when installing the hard drive:

o

When installing a 9.5-mm SATA hard drive and a hard drive spacer, install the long hard drive
screws that are stored on the hard drive spacer.

o

When installing a midline SATA hard drive or a SAS hard drive, install the standard hard drive
screws that ship with the server blade.

To install the component:

1.

Power down the server blade (on page

11

).

2.

Remove the server blade (on page

12

).

3.

Remove the access panel (on page

13

).

4.

Remove the air baffle.

5.

Install the hard drives.

CAUTION:

When installing midline SATA hard drives in the server blade, always install the

standard hard drive screws provided with the server blade. Installing the long hard drive screws

located on the hard drive spacer can damage the hard drive.