Option rom configuration for arrays – HP ProLiant BL280c G6 Server-Blade User Manual

Page 61

Advertising
background image

Software and configuration utilities 61

Mozilla Firefox 2.0 or later

For Linux servers, see the README.TXT file for additional browser and support information.
For more information, see the Configuring Arrays on HP Smart Array Controllers Reference Guide on the
Documentation CD or the HP website (

http://www.hp.com

).

Option ROM Configuration for Arrays

Before installing an operating system, you can use the ORCA utility to create the first logical drive, assign

RAID levels, and establish online spare configurations.
The utility also provides support for the following functions:

Reconfiguring one or more logical drives

Viewing the current logical drive configuration

Deleting a logical drive configuration

Setting the controller to be the boot controller

If you do not use the utility, ORCA will default to the standard configuration.
For more information regarding array controller configuration, refer to the controller user guide.
For more information regarding the default configurations that ORCA uses, refer to the HP ROM-Based Setup

Utility User Guide on the Documentation CD.

Re-entering the server serial number and product ID

After you replace the system board, you must re-enter the server blade serial number and the product ID.

1.

During the server blade startup sequence, press the F9 key to access RBSU.

2.

Select the Advanced Options menu.

3.

Select Service Options.

4.

Select Serial Number. The following warnings appear:
WARNING! WARNING! WARNING! The serial number is loaded into the system during

the manufacturing process and should NOT be modified. This option should only

be used by qualified service personnel. This value should always match the

serial number sticker located on the chassis.
Warning: The serial number should ONLY be modified by qualified personnel.

This value should always match the serial number located on the chassis.

5.

Press the Enter key to clear the warning.

6.

Enter the serial number and press the Enter key.

7.

Select Product ID. The following warning appears:
Warning: The Product ID should ONLY be modified by qualified personnel. This

value should always match the Product ID on the chassis.

8.

Enter the product ID and press the Enter key.

9.

Press the Esc key to close the menu.

10.

Press the Esc key to exit RBSU.

11.

Press the F10 key to confirm exiting RBSU. The server blade automatically reboots.

Advertising