Side Panel—Displays the status of the side panel of the drive enclosure, or box. The following
values are possible:

◦

In Place—The side panel is closed.

◦

Removed—The side panel is not in place or not completely closed.

◦

Unknown—The Storage Agents do not recognize the side panel status. You may need
to upgrade your software.

◦

No Panel Detection—This storage system does not support side panel detection.

•

Duplex Option—Displays the duplex option installed in this storage system. The following
values are possible:

◦

Duplex Top—This storage system is the top part of a duplexed unit.

◦

Duplex Bottom—This storage system is the bottom part of a duplexed unit.

◦

None—A duplex option is not installed.

•

Power Supply Status—Displays the status of the redundant power supply. The following values
are possible:

◦

OK—All component power supplies that make up the redundant power supply are in
normal working order.

◦

Degraded—One of the component power supplies that make up the redundant power
supply has failed. The drive system (either a drive subsystem or a power supply for the
main unit) continues to operate; however, if the remaining power supply should fail, the
drive system loses power and data loss could occur. To correct this situation, schedule a
time to bring the device down and replace the failed power supply.

◦

Unknown—The Storage Agents do not recognize the redundant power supply. You may
need to upgrade your software.

◦

No Redundant Power Supply—This ProLiant server does not support a redundant power
supply.

•

Paths—Displays the status and role of each data path to the storage system (for multipath
capable hardware only). The following values are possible:

◦

Path—Indicates the path to the storage system. Each path is identified by a descriptor.
For example, "Port 2E Box 1" indicates a path from the host adapter external port number
2 ("Port 2E") to the first box.

◦

Status—Indicates the status of the data path. Possible values are:

OK—The path is operational.

–

–

Link down—The path is not operational.

–

Unknown—The path status cannot be determined.

◦

Role—Indicates the role of this path in the configuration. Possible values are:

–

Active—This path is the preferred data path to the storage system.

–

Alternate—This path is the alternate data path to the storage system.

–

Unknown—The role of this path cannot be determined.