background image

◦

High - indicates the expand priority is high.

◦

Unknown - indicates that the expand priority is not recognized. You may need to upgrade
the Storage Agents.

•

Controller Status displays the status of the controller hardware. The following values are valid:

OK - The controller is operating normally.

◦

◦

Failed - The controller has failed and is no longer operating.

◦

Offline - The controller is offline.

◦

Redundant Path Offline - There are multiple connection paths to this controller. At least
one connection path is available and at least one connection path is not available.

◦

Unknown - Indicates that the Storage Agents are unable to determine the status of the
controller. You may need to upgrade the Storage Agents.

•

Current Role displays the array controller's current role for duplexed array controllers. The
following values are valid:

◦

Not Duplexed - This array controller is not duplexed.

◦

Active - This duplexed array controller is the active controller.

◦

Backup - This duplexed array controller is the backup controller.

◦

Unknown - Indicates that the Storage Agents are unable to determine the role of the
controller. You may need to upgrade the Storage Agents.

•

Redundancy Type displays the type of redundant configuration. The following values are valid:

Not Redundant - This array controller is not in a redundant configuration.

◦

◦

Firmware Active/Standby - The array controller is using an active/standby algorithm
implemented in the controller firmware and the operating system driver.

◦

Firmware Primary/Secondary - The array controller is using a primary/secondary algorithm
implemented in the controller firmware and the operating system driver.

◦

Unknown - Indicates that the Storage Agents are unable to determine the type of
redundancy for the controller. You may need to upgrade the Storage Agents.

•

Redundancy Error displays the redundancy error for the controller. The following values are
valid:

◦

No Failure - No failures have been detected.

◦

No Redundant Controller - No redundant controller is installed.

◦

Different Hardware - The other controller indicates a different hardware model.

◦

No Link - A link to the other controller could not be established.

◦

Different Firmware - The other controller indicates a different firmware version.

◦

Different Cache - The other controller indicates a different cache size.

◦

Other Cache Failure - The other controller indicates a cache failure.

◦

No Drives - This controller cannot see any attached drives, but the other controller can.

Storage agent