HP Insight Management Agents User Manual

Page 75

Advertising
background image

High - indicates the expand priority is high.

Unknown - indicates that the expand priority is not recognized. You may need to upgrade
the Storage Agents.

Controller Status displays the status of the controller hardware. The following values are valid:

OK - The controller is operating normally.

Failed - The controller has failed and is no longer operating.

Offline - The controller is offline.

Redundant Path Offline - There are multiple connection paths to this controller. At least
one connection path is available and at least one connection path is not available.

Unknown - Indicates that the Storage Agents are unable to determine the status of the
controller. You may need to upgrade the Storage Agents.

Current Role displays the array controller's current role for duplexed array controllers. The
following values are valid:

Not Duplexed - This array controller is not duplexed.

Active - This duplexed array controller is the active controller.

Backup - This duplexed array controller is the backup controller.

Unknown - Indicates that the Storage Agents are unable to determine the role of the
controller. You may need to upgrade the Storage Agents.

Redundancy Type displays the type of redundant configuration. The following values are valid:

Not Redundant - This array controller is not in a redundant configuration.

Firmware Active/Standby - The array controller is using an active/standby algorithm
implemented in the controller firmware and the operating system driver.

Firmware Primary/Secondary - The array controller is using a primary/secondary algorithm
implemented in the controller firmware and the operating system driver.

Unknown - Indicates that the Storage Agents are unable to determine the type of
redundancy for the controller. You may need to upgrade the Storage Agents.

Redundancy Error displays the redundancy error for the controller. The following values are
valid:

No Failure - No failures have been detected.

No Redundant Controller - No redundant controller is installed.

Different Hardware - The other controller indicates a different hardware model.

No Link - A link to the other controller could not be established.

Different Firmware - The other controller indicates a different firmware version.

Different Cache - The other controller indicates a different cache size.

Other Cache Failure - The other controller indicates a cache failure.

No Drives - This controller cannot see any attached drives, but the other controller can.

Storage agent

75

Advertising