HP ProLiant DL360 G5 Server User Manual

Page 55

Advertising
background image

Hardware options installation 55

CAUTION: When routing cables, use the cable trough between fan modules 1 and 2. Be sure the cables

do not interfere with fan module installation. Be sure to route the cables around the access panel mounting
pin bracket so as not to interfere with access panel installation.

13.

Connect the hard drive backplane power cable to the system board ("

System board components

" on

page

11

).

14.

Install the fan module ("

Remove and install a fan module

" on page

22

).

15.

Install the air baffle.

16.

Install the access panel (on page

20

).

17.

Slide the server into the rack.

18.

Power up the server (on page

18

).

Installing an HP Smart Array P400i Controller cache module and battery pack

1.

Power down the server (on page

18

).

2.

Extend the server from the rack (on page

19

).

3.

Remove the access panel (on page

20

).

4.

Remove the air baffle. ("

Remove the power supply air baffle

" on page

21

, "

Remove the processor

air baffle

" on page

22

)

5.

Remove fan modules 1 and 2 ("

Remove and install a fan module

" on page

22

).

6.

Remove the HP Smart Array P400i Controller ("

Removing an integrated HP Smart Array E200i

Controller or an HP Smart Array P400i Controller

" on page

50

).

Advertising