SFS20 RAID5 and ADG performance

B–7

•

Each array populated with twelve 250GB disks, configured as one 2TB LUN with ADG (RAID6)

redundancy

•

Voltaire InfiniBand interconnect

•

RAID5 configuration

•

Four SFS20 arrays attached to each Object Storage Server

•

Each array populated with eleven 250GB disks, configured as one 2TB LUN with RAID5

redundancy

•

Voltaire InfiniBand interconnect

All results are based on tests using new, empty file systems with default MDS and OST mount options and

without quotas enabled.

Each client node writes a single file of 4GB with one and four stripes to a single Object Storage Server.

As a rule of thumb, write operations are slower when ADG redundancy is used than when RAID5

redundancy is used; read operations are roughly equivalent.