The installation space, Product clearances, Side-by-side installations – GE ZIDI240BII User Manual

Page 4: Design guide

Advertising
background image

Design Guide

4

THE INSTALLATION SPACE

IMPORTANT: Double-Drawer Refrigerators are
designed to be built-in only. They cannot be used
free-standing.

NOTE: The unit is designed to be flush with the
surrounding cabinets.

Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is required.

An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back
wall as shown. Electrical must be located on rear wall
as shown. NOTE: GFCI (ground fault circuit interrupter)
is not recommended.

PRODUCT CLEARANCES

When installed
in a corner:

Allow 2-1⁄ 2" min. clearance between Double-Drawer
and adjacent cabinet, wall or other appliances.
Allow 22" min. clearance from the front for drawer
opening.

NOTE: Clearances are based on the noted 2-1⁄ 8" handle
standoff depth.

• Test the drawer openings. Carefully open and close

the drawers. The drawers should not rub or catch on
adjacent cabinetry. Notify the installer if the drawers
make contact with cabinetry.

Choose the location:
• These products may be closed in on the top and

three sides as long as the front is unobstructed for
air circulation and proper access to the drawers.

• Do not install these products where the temperature

will go below 55°F (13°C) or above 90°F (32°C).

• These products are not designed to be stacked one over

the other.

SIDE-BY-SIDE INSTALLATIONS –

Stainless Steel Models Only

For a complete refreshment center, install a Double-Drawer
Refrigerator beside a Beverage Center, Wine Chiller/
Wine Reserve, Fresh-Food Refrigerator or Bar Refrigerator
with Icemaker.

• A side-by-side installation requires at least a 47-1/2" wide

opening. No trim kits required.

• Products must operate from separate, properly grounded

receptacles.

34-1/2"-35"

24"

47-1/2" Min.

1-1/2"

9"

10-1/2"

9"

10-1/2"

14"

15"

Locate

Outlet

Allow 22" clearance
at the front for full
extension of drawers.

FOR MODEL ZIDS240 WITH STAINLESS STEEL DRAWERS AND HANDLES

Clearance for Door

Opening 2-1/2" min.

Countertop

Double-Drawer

22" min.

Advertising