The installation space, Product clearances, Side-by-side installations – GE ZIDI240BII User Manual

Page 5: Design guide

Advertising
background image

Design Guide

5

THE INSTALLATION SPACE

IMPORTANT: Double-Drawer Refrigerators are
designed to be built-in only. They cannot be used
free-standing.

NOTE: The drawers should be flush with the surrounding
cabinets.

Additional Specifications
• A 120 volt 60Hz., 15 or 20 amp power supply is required.

An individual properly grounded branch circuit or circuit
breaker is recommended. Install a properly grounded
3-prong electrical receptacle recessed into the back
wall as shown. Electrical must be located on rear wall
as shown. NOTE: GFCI (ground fault circuit interrupter)
is not recommended.

PRODUCT CLEARANCES

When installed
in a corner:

Allow 2-1⁄2" min. clearance between Double-Drawer and
adjacent cabinet, wall or other appliances. Allow 23-1⁄8"
min. clearance from the front for drawer opening.

NOTE: Custom handle clearances may vary depending on
the standoff of the custom handles.

• Test the drawer openings. Carefully open and close

the drawers. The drawers should not rub or catch on
adjacent cabinetry. Notify the installer if the drawers
make contact with cabinetry. NOTE: When installing
custom panels and handles, use above clearances as
a general guide but adjust according to the installation.

Choose the location:
• These products may be closed in on the top and

three sides as long as the front is unobstructed for
air circulation and proper access to the drawers.

• Do not install these products where the temperature will

go below 55°F (13°C) or above 90°F (32°C).

• These products are not designed to be stacked one over

the other.

Black or Stainless Steel Toekick Options
• These products are shipped with two toekicks,

a stainless steel and a black toekick. For shipping
purposes, one of the toekicks will be secured to
the back of the unit and the second will be installed,
in place, on the unit. Keep the unused toekick,
and other unused or removed parts, for future use.

Allow 22" clearance
at the front for full
extension of drawers.

FOR MODEL ZIDI240 WITH CUSTOM DRAWER PANELS AND HANDLES

Clearance for Door

Opening 2-1/2" min.

Countertop

Double-Drawer

23-1/8" min.

*Custom handle clearances may vary, depending on the

standoff of the custom handles.

SIDE-BY-SIDE INSTALLATIONS –

Custom Panel Models Only

For a complete refreshment center, install a Double-Drawer
Refrigerator beside a Beverage Center or Wine Chiller/
Wine Reserve.

• A side-by-side installation requires at least a 47-1/2" wide

opening. No trim kits required.

• Products must operate from separate, properly grounded

receptacles.

34-1/2"-35"

24"

47-1/2" Min.

1-1/2"

9"

10-1/2"

9"

10-1/2"

14"

15"

Locate

Outlet

*NOTE: Additional clearances

may be required.

Advertising