MONITOR Menu

UNITS - List all Model Numbers of units in the rack by slot #


UNIT n - Lists the monitored parameters and values for the unit in slot “n”


UNITNAME n – Set the name of the card for identification purposes. On the web
browser interface, this appears under the Card ID.

ALARMS – Presents number list of all rules currently programmed to test for
alarm conditions

DELALARM n – deletes the specified alarm rule

ADDALARM n – adds a new rule to the list of alarm rules. See the section on
alarms for alarm rule formatting

RESET – erases all alarm rules and replaces them with the default alarm
conditions. This takes about a minute, during which time the unit will not be able
to do anything else.

TEMPMODE n – used to specify if temperatures are displayed in Celsius or
Fahrenheit notation.

TIMEOUT n – sets the time after which a unit removed from the rack will be
removed from the GUI display.

EMAIL Menu


CONFIG – Shows the current configuration.

DOMAIN n – Enters the source domain name to be used when sending email
notifications.

EMAIL n – Email address to send notifications.

RETRY n – Sets the number of retries that the units attempts to send emails
Default value = 10.

DELAY n – Sets the delay time in seconds between email attempts. Default
value = 900 seconds.

START – Starts the email notification system.

STOP – Stops the email notification system.