INSTALLATION

THIS INSTALLATION SHOULD BE MADE BY A QUALIFIED SERVICE PERSON AND
SHOULD CONFORM TO THE NATIONAL ELECTRICAL CODE, ANSI/NFPA 70 AND LOCAL
CODES.

To install the MTX-986-UTP-SL or MRX-986-UTP-SL it is first necessary to mount the rack
flanges to the unit.

For rack mounting the ears are installed on the
sides of the unit with the surfaces that have
oval holes flush with the front of the unit as in
Figure 1. Mount the ears with the #10 flathead
screws provided. To mount in the rack cabinet,
use mounting screws that are appropriate for
the rack cabinet being used. When mounting
the MTX-986-UTP-SL or MRX-986-UTP-SL in
a rack configuration, it is recommended that
sufficient airflow is available through the unit.
This can be achieved by leaving a 1RU slot
above the unit open for air movement and by
leaving open space along the sides of the unit.

For mounting the unit flush to a wall or other
rigid surface, the ears may be installed on the
sides with the oval holes flush with the bottom of
the unit as in Figure 2. Mount the ears with the
#10 flathead screws provided. Mount the unit to
a rigid surface using #10 (5mm) screws.


POWER SOURCE

The internal power supply accepts universal line voltage. Any mains supply from 100 to 240
VAC, 50 to 60 Hz, may be used without modification or adjustment. A universal power
connector is provided on the rear of the unit to facilitate connection to the power mains.


POWER CONNECTION

The unit is supplied (in the US and UK only) with a three conductor power cord. The “ground”
conductor is directly connected to the chassis.

FIBER CONNECTION

The fiber optic connection is made via a FC connector located at the back of the unit. Be sure to
allow sufficient room for the required minimum bend radius of the fiber cable used.