2.4.4 Zeroing on a 25-Meter Range. This procedure is used
to zero the AN/PEQ-2A to the weapons and distances listed
in Table 2-7. Refer to Tables 2-1, 2-2, and 2-3 for adjuster
rotation and resultant direction of shot group movement.

a. On a 25-meter zeroing target, mark the designated

strike point and designated strike zone for the
weapon you are using (see Table 2-7).

b. Mount the target on an “E” silhouette or other

suitable surface at 25 meters.

c. Mount the AN/PEQ-2A to the weapon.

d. Rotate the Mode Selector to Position 1 (AIM LO). If

necessary, install the Aim Neutral Density Lens Cap
to eliminate excessive blooming. In high ambient
light conditions, use Position 3 (AIM HI).

e. While looking through a night vision device, activate

the Aim Laser in continuous mode by double-tapping
the Fire Button.

f. Direct the Aim Laser at the center of the target.

g. Fire a 3-round shot group and note the center of the

shot group relative to the designated strike point.
Re-tighten Rail Grabber Bracket and the AN/PEQ-
2A thumbscrew.

h. Rotate the Aim Laser Adjusters to move the center

of the shot group to the designated strike point.

i. Fire another 3-round shot group and again observe

the center of the new shot group relative to the
designated strike point.

j. When 2 out of 3 rounds are in the designated strike

zone, the AN/PEQ-2A / weapon combination is
zeroed.