Troubleshooting – ADC AD-410 User Manual

Page 108

Advertising
background image

104

SECTION VI

TROUBLESHOOTING

IMPORTANT: YOU MUST DISCONNECT and LOCKOUT THE ELECTRIC SUPPLY and

THE GAS SUPPLY or THE STEAM SUPPLY BEFORE ANY COVERS or
GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS
FOR CLEANING, ADJUSTING, INSTALLATION, or TESTING OF ANY
EQUIPMENT per OSHA
(Occupational Safety and Health Administration)
STANDARDS.

The information provided will help isolate the most probable components associated with the difficulty
described. The experienced technician realizes, however, that a loose connection or broken/shorted wire may be
at fault where electrical components are concerned... not necessarily the suspect component itself. Electrical
parts should always be checked for failure before being returned to the factory.

IMPORTANT: When replacing blown fuses, the replacement must be of the exact rating as the fuse

being replaced. The information provided should not be misconstrued as a hand-
book for use by an untrained person in making repairs.

WARNING: ALL SERVICE and TROUBLESHOOTING SHOULD BE PERFORMED BY A

QUALIFIED PROFESSIONAL or SERVICE AGENCY.

WARNING: WHILE MAKING REPAIRS, OBSERVE ALL SAFETY PRECAUTIONS

DISPLAYED ON THE DRYER or SPECIFIED IN THIS MANUAL.

A. No Display...

1. “EMERGENCY STOP” button pushed in.

2. Service panel fuses blown or tripped breaker.

3. Blown F1 (fuse 1) or F2 (fuse 2) on right hand control panel.

4. Blown F4 (fuse 4) on right hand control panel.

5. Failed microprocessor controller (computer).

6. Optional sprinkler circuit emergency relay not engaged ...

a. Service panel fuse blown or tripped breaker.

b. Sprinkler circuit high limit has tripped.

NOTE: SPRINKLER MUST HAVE POWER FOR THE DRYER TO OPERATE.