Installation

Motor Installation

All DQC units are shipped with motors mounted at

the factory.

Fan Installation

1. DQC Series fans are compact, versatile and may

be mounted in any position. The recommended

mounting location of the fan is a minimum of 15

linear feet from the dryer exhaust port in order to

avoid moist or wet lint to gather in the fan. If a

lint trap is being used between the fan and the

dryer, the fan can be mounted closer than the

recommended 15 feet. The DQC fan warranty is

increased from three(3) to five(5) years if FanAm’s

2100 Series lint trap is used in conjuction with the

fan.

2. Because this unit has rotating parts, safety

precautions

should be excercised during

installation, operation and maintenance procedures.

3. WARNING! Unless specifically built for hazardous

environments, do not use the fans where the elec-

trical system could ignite combustible or flammable

material.

4. Remove unit from package and inspect within 15

days after receipt. If damaged, report damage to

carrier. Do NOT operate this unit with visible damage

to the blower or impeller assembly. Turn centrifugal

impeller by hand to assure free rotation.

5. CAUTION: Before proceeding with installation, make

sure there is no electrical connection. All wiring should

be in accordance with local ordinances and the

National Electric Code.

WARNING: Check voltage to the fan to assure it

corresponds with the motor name plate.

6. CAUTION: Always vent this unit to the outside,

NOT into spaces within ceilings or walls, attics, crawl

spaces, garages, etc.

7. Keep drywall spray, construction dust, etc., off

and out of the impeller assembly to avoid motor bear-

ing damage, noise, or unbalanced impellers.