INSTALLATION INSTRUCTIONS

for Vinyl Windows without Nailing Fin (JII011)

4

PREPARE WINDOW OPENING - CONTINUED

3

Interior

Width of

rough opening

12"

Measure

frame

width

Sealant

joints

Liquid

applied

flashing

Continuous

support

1/2"

PREPARE MASONRY OPENING WITH BUCK

1. Seal any joint larger

than 1/16" in the buck
and between the buck
and the concrete/
masonry with sealant.

2. Cover the buck and

the surrounding
concrete/masonry at
the head and jambs
with liquid applied
flashing as shown.

3. If installing into a

four-sided buck,
seal the sill in a
similar manner.

Note!

Where the

window will sit on the

sill, shim to provide

continuous support to
the sill. This shimming
must be 1/2" shorter
than the width of the
window frame, be
1/4" narrower than the
depth of the window
frame sill, should level
the rough opening sill
and be no more than
1/4" thick.
4. Center the continuous support on the sill of the opening, flush to the

exterior edge and leaving a 1/2" gap at the ends. Secure in place.

END of Buck Instructions, SKIP to section 4, “INSTALL WINDOW.”

PREPARE STUD-FRAMED WALL

PREPARE BUILDING WRAP

Trim building wrap
flush with the edges of
the rough opening (or
follow manufacturers’
instructions for
trimming).

PREPARE/SHIM THE SILL

1. Use self adhesive flashing to waterproof the sill.
2. Flashing must have at least 1"

of material wrapped below
the sill onto the vertical wall.
Flashing width must be at
least frame width + 1".

3. Measure the width of the

frame and subtract 1/4".
Transfer this measurement
from the outside edge of the
rough opening sill and draw
a line all along the rough
opening sill. This is where the
back of the flashing will sit.

4. Cut a piece of flashing the

length of the sill plus 12".

5. Place flashing on rough

opening sill, wrapping the
flashing up 6" on each jamb
as shown.

6. Pull release tape and set

flashing into place.

7. Fold the flashing down onto

the sheathing. Staple flashing
to the wall, if needed, and seal
the corner edges as shown.

8. Smooth out any bubbles or

creases with a J-roller.

9. Install the continuous support

as follows:

Note!

Where the window will

sit on the sill, shim to provide

continuous support to the

sill. This shimming must be

1/2" shorter than the width

of the window frame, be 1/4"

narrower than the depth of

the window frame sill, should

level the rough opening sill

and be no more than 1/4"

thick.
10. Align the shimming on the

sill flush with the exterior

and centered between the side jambs. If installing a mulled unit,

leave gaps at the mull joint(s) so they don't sit on the shimming and
tack into place or secure with sealant.

Continuous

support

Depth of

window

minus 1/4"

Flashing

Advertising