VR15 VR12

VR16

GR-METER

LIM CV

LIM REF V OP1 ZERO VU

Diagram 8

14. Servicing

VR11

VR9

VR6

GR-ZERO

12AX7WA

6922

GR-AUDIO

TUBE LOCATION

CALIBRATION TRIM POT LOCATION

c

o

r

e

The CORE requires calibration for 3 sections of its circuitry:

I) - VU METER- Adjust: +4dBu (1.228 Volts RMS) = “0” VU, Meter “GR” zero set

®

ii) - ELOP COMPRESSOR- Adjust: Gain Reduction (Audio & Meter GR)
iii)- FET PEAK LIMITER- Adjust: reference voltage & FET control voltage

Tools required:

-

Audio Tone Generator (oscillator)

-

Audio Analyzer or a voltmeter capable of reading both DC & AC voltages.

Initial settings:

-

Mic/Line Input select switch: Out = LINE IN Enable

-

120Hz HP filter switch: Out = Disable

-

Gain switch: Out = LOW

-

48V Phantom switch: Out = OFF

-

Phase Invert switch: Out = 0

-

Input Level Attenuator: Set at Minimum

-

Compressor Section: Switch = Bypass; Compression, Attack & Release =12:00 O'clock

-

Shelving EQ section: High/Low controls set both = 12:00 O'clock.

-

Mid EQ section: Boost/Cut control = 12:00 o'clock, Frequency range select switch = 100Hz-1kHz,

Frequency sweep control = MIN

-

Peak Limiter section: Limiting = MIN, Release = 12:00 o'clock

-

Output Gain Control: 12:00 o'clock

15. Core Calibration Procedure

2A (T) FUSE

11