MJM Yachts 36z Express User Manual

Page 33

Advertising
background image

CHAPTER 6

House and Generator battery switches
These rocker switches with sliding cover are located

on the upper right side of the DC panel with a Battery
Combiner between. When the battery combiner

switch is pushed DOWN, it is OFF. Pushed in UP it
is ON. It is recommended to leave it in the middle

AUTO position where it stays active at over 13.6 volts
and deactivates below 12.7 volts.


DC Breaker Panel This custom MJM panel Includes

digital readouts for voltage and amperage drain of the
House Bank in Position 1 of the display and reads

condition of the generator battery in Position 2.

To use DC components, the HOUSE battery bank
Rocker switch must be ON, the top main DC dis-
connect breaker on the panel must be ON,
and the component’s respective breaker must be ON.


Windlass Operation The windlasss uses Engine

Batteries, so it is necessary to have the Engine
Battery switches turned ON and ideally have the

engines operating when using the windlass.

The GENERATOR battery switch must remain on
when running.

Engine Battery Switches The two Engine Battery

Switches are located on the top right corner of the

AC Panel. To start the engines or use the windlass,

the engine START battery switches must remain
ON. The Combiner switch between, manually in the

UP position combines the two engine start batteries
should one of them fail. The DOWN position is OFF

and the MIDDLE position is AUTOMATIC combining
of the two engine batteries and also the house bank

if voltage is under 12.7 volts…deactivating when

over 13.7 volts.

6.2 AC PANEL

Breaker Panel The main AC disconnect breakers

for AC #1 and AC #2 are located in the middle of the
AC Panel. They must be ON for shore-power to

supply the boat’s AC power.

AC Shore 1 (left half) includes breakers for those
items which can be handled by the Mastervolt

Inverter. To use the inverter, (1) the house battery
selector switch must be ON and (2) the inverter

breaker on the AC panel must be ON. Refer to the
inverter/charger manual for more information.


When the Shore 1 shore-power cable is attached

and the Shore 1 select breaker is ON, Shore 1 will
supply AC power to AC Panel #1.