6.8

The bonding system of your boat connects all underwater metallic fittings to the sacrificial zinc
and the boat’s negative bus bar. In order for the zinc to protect an underwater part, the
connection must be clean and secure. The green wires that make up this system are not normally

current carrying.

6.9

Please read and understand the important safety precautions included in the included ISO CE
Mark approved Owner’s Manual” concerning electrical safety.

6.10 BREAKER & FUSE LOCATIONS & SPECIFICATIONS

6.11 RAYMARINE FUSE LIST (Includes Options)

Chart Plotter
Autopilot X-Can

SeaTalk ng
SeaTalk

Network Switch
RD424D Digital Radar

RS125 GPS
DSM 300 Fishfinder

Ray55 VHF radio
SR100 Sirius Receiver

SR6 Sirius Receiver / Network Switch
AIS 500 Transceiver

6.12 IN-LINE and ANL FUSE LIST/LOCATION

Item / Fuse Label

1
2
3
4

5

6

7

8

BONDING

ELECTRICAL SAFETY

Bilge Pump 1
Bilge Pump 2
Bilge Pump 3
Bilge Pump 1

Bilge Pump 2

Bilge Pump 3

Stereo Memory

DVD Memory

ELECTRICAL SYSTEM

Size

5 amp
5 amp
5 amp

7.5 amp

7.5 amp

7.5 amp

15 amp

15 amp

Type

AGC
AGC
AGC

ATC

ATC

ATC

ATC

ATC

Fuse Block next to House Battery 1 (Stbd

Settee Hatch)

Fuse Block next to House Battery 1 (Stbd

Settee Hatch)

Fuse Block next to House Battery 1 (Stbd

Settee Hatch)

Fuse Block next to House Battery 1 (Stbd

Settee Hatch)

Fuse Block next to House Battery 1 (Stbd

Settee Hatch)

7 Amps
10 Amps
3 Amps
3 Amps

1 Amp
15 Amps (10A breaker)
1 Amp
8 Amps
10 Amps
2 Amps
2 Amps
5 Amps

In the Bilge Pump Switch at the Dash
In the Bilge Pump Switch at the Dash
In the Bilge Pump Switch at the Dash

Location