CHAPTER 6

ACTIVATE AC PANEL 1: When the green LED light appears on AC 1 Panel, turn ON double
Generator Selector switch for AC 1 ONLY. There is a delay until Volts (about 115) register in the

digital display over AC-1.

ACTIVATE AC PANEL 2: Select “CHARGE” on the Xantrex Panel and when the light comes on
Green, the double-Generator Selector switch for AC 2 can be turned ON.


See that AC volts are now reading on the digital meter over AC Panel 2.


TURN BREAKERS ON for the items you wish to operate.

Note: if the generator starts, but no AC voltage is seen at the panel, check first that the selector

switches (sliding interlocks) at the top of the AC panel are ON. If so and still no voltage reading, there
is a possibility the generator was overloaded and the AC breaker on the generator itself) has
tripped due to a momentary overload. Open the generator cover and reset (pull up) the AC Output
Circuit Breaker.

STOP: First, remove any electrical load from the generator Allow the engine to run for a 3-5 minute
cool-down period. Depress STOP momentarily on the lower part of the rocker switch.

Break-In Period Change engine oil and filter at 50 hours and again at 100 hours. Oil consumption is
greater until piston rings are seated. Maintain at least a 75% load on the generator for the first 100
hours, varying the load to help seat the rings.