Operating Procedures

1. Plug the unit into a grounded 100~120V outlet,

preferably with a ground fault interrupt (GFI) to prevent
fire, injury or electrocution.

2. Open the cover to wipe the tank with a clean cloth.

3. Dropping objects into the tank can damage the circuity,

so gently place the object to be cleaned into the tank.

Note: If a sharp tool touches another metal object
during the cleaning cycle, the ultrasonic action can
dull the edge. Use plastic baskets so that such tools
don't touch the metal.

4. Fill the tank with enough water to cover the item but

not exceed the MAX line. The unit can be damaged if it
is operated without sufficient water. If desired, a few
drops of mild phosphate-free detergent may be added
to the water. The use of disenfectants is not
recommended as they may produce harmful vapors. If
you use a dipping basket, the unit's stainless steel tub
must also be filled with water.

5. Press the "ON" button to start the cleaning cycle. The

unit will automatically shut off after 3 minutes. Never
leave the unit unattended during operation. In some
cases, pre-soaking or repeated cleaning cycles may be
required. After extended operation, if the water
becomes too hot (over 158°F / 70°C) replace with cool
water before continuing.

6. To stop the unit during a cleaning cycle, press the

"OFF” button.

7. When you are finished, unplug the unit and clean the

exterior, buttons and electrical cord with a damp cloth.

PRECAUTIONS

The Mini Unltrasonic Cleaner is not a toy and it is not
intended for use by children.

x

DO NOT disassemble the unit.

x

DO NOT use near a sink, tub or other water source
where there is danger from electrocution.

x

DO NOT use if the electrical cord is damaged.

x

DO NOT clean with abrasive or harsh solvents.

x

DO NOT submerge the unit or allow water to seep
into the circuitry.

x

DO NOT use if the unit becomes hot to the touch.
Discontinue use immediately, unplug, and wait until
the unit cools completely before resuming use.

x

DO NOT use on fragile stones such as turquoise,
pearls, and opals, coated metals, or live creatures.

Advertising