Yetter 2967-035 TITAN Universal Face Plate Mounted Floating Residue Manager User Manual

Page 15

Advertising
background image

15

MAINTENANCE

Lubrication Symbols

Lubricate with grease at hourly interval indicated on symbol.



Lubrication Intervals

IMPORTANT: The recommended service intervals are based on normal

conditions; severe or unusual conditions may require more frequent
lubrication.

Perform each lubrication and service procedure at the beginning and end of each

season.

Clean grease fittings before using grease gun, to avoid injecting dirt and grit into the

bearing. Replace any lost or broken fittings immediately. If a fitting fails to take

grease, remove and clean thoroughly, replace fitting if necessary. Also check for

failure of adjoining parts.


BEARING REPLACEMENT INSTALLATION


1. When assembling the spoke wheels, bearing assembly and hubcap, be sure

to align the grease transfer hole in the spoke wheel with the groove in the
hubcap and hole in the hub to allow grease passage.

2. Assemble the wheels, hubs and caps


3. Grease the wheel/hub/bearing assembly.

Advertising