Connection with exhaust conduct

Place draught-diverter system supplied with the device between the exit of the heater
and the gas exhaust conduct. The tubes that connect with the chimney are of diameter
150 and should be as short as possible.

2.2.4 First start-up

• Verify that the machine is stable and level upon first start-up.
• Check that all connections and drains are correctly established.
• Check that the device is connected to earth correctly.
• Take away brackets transport (see instruction at the end).
• Check that all switches are in their position 0.
• Turn the circuit breaker with guard to position 1.
• Check that the pump (gas heating) rotates in the correct direction.


Note: If the machine turns the wrong way, check the technical service centre of
the manufacturer.

Attention: Take care not to touch or come close to any moving parts.

Mount all protection panels back on the machine.


2.3 Adaptation of the device to another type of gas

2.3.1 Actions to be taken

• Dismount the access panels of the heater on the side of the dirty laundry.
• Unscrew the 4 fixing bolts of the gas ramp as well as the bolt of the hose of the

gas connection.

• Extract the ramp.
• Unscrew the injectors and replace them.
• Proceed in reverse order to mount the system and check that the gas feed

pressure at the entry valves of the module is in agreement with the pressures
indicated in the table below (device operating).

• Seal the air adjustments with a little paint.