7. PROBLEMS DURING OPERATION AND START-UP


Problem

Check

--------------------------------------------------------------------------------------------
Cycle does not start

- doors not closed correctly

- emergency stop activated

- contact breaker or

electricity outage

--------------------------------------------------------------------------------------------
Control panel does not

- fuses tripped

light up

- emergency stop activated

- processor off

- electricity outage

--------------------------------------------------------------------------------------------
Cycle starts but drum

- fuse of regulator tripped

does not turn

- press yellow indicator light

on front side when it is on

--------------------------------------------------------------------------------------------
Cycle starts but water

- water inlet closed

does not enter

- pressure switch out of

service

- electronic valve out of

service

- fuse tripped

- electronic valve of inlet out

of service

--------------------------------------------------------------------------------------------
Cycle starts but water

- pressure switch out of

inflow does not stop

service

- electronic valve dirty

- tub pressure switch

clogged

- drainage valve still open

--------------------------------------------------------------------------------------------
Cycle starts but heating

- required water level not

does not engage

reached

- fuse tripped

- contact coil heating out of

service

- HS probe

--------------------------------------------------------------------------------------------
Heating is on but

- resistor out of service

temperature does not rise