2.3.2 Table of adjustments and flow rates



Gas type

G20 (1)

G25 (2)

G31 G31

Pres.
feed.(mbar)

20 20 37 50

Injector
marking

180 200 120 110

Adjustment of
air pres.

Max opening of
vent

Idem Idem Idem

Flow of burner 2.64(cubic m/h) 3.07(cubic m/h) 1.96 (kg / h)

1.96 (kg / h)

Nominal heat
flow kW (hi)

24.9

24.9

24.9

24.9



(1)

Identical adjustment for G25 at 25 mbar

(2)

Germany only


* G20: natural gas type H (Lacq)
* G25: natural gas type L (Groningen)
* G31: propane