10xbd 4xbd bd, 1,5 x bd – Sandvik Coromant Silent tools - application guide User Manual

Page 36

Advertising
background image

34

10xBD

4xBD

BD

3. Turning

Boring bars – general

• Surface finish of ~1 µm is required to ensure sufficient clamping

contact

• Recommended clamping length is 4 × BD. If possible, we recom-

mend using a clamping length of 6 × BD for boring bars over 200
mm (7.87 inch)

• Cylindrical boring bars in split sleeves. Recommended clamping

tolerance is ISO H7

• Split bushing material, minimum 45 HRC to avoid permanent

deformation

• If a large bar, use a double bearing cap
• For best clamping stability use a split boring bar holder

Let the design and dimensions of the component decide the dia-
meter and length of the boring bar. For best clamping stability, first
choice is Coromant Capto coupling or split sleeves. The diameter
of the bore and the length needed to reach the bottom will indicate
what type of boring bar to use.

1-1,5 x BD

Advertising