Wixey WR100 Type 2 DIGITAL CALIPERS with FRACTIONS User Manual

Wixey Tools

Advertising
background image

Wixey

DIGITAL CALIPERS with FRACTIONS
MODEL WR100 Type 2

INSTRUCTIONS



Measurements:












Functions:

ON/OFF- turns the power completely on or off. When turned ON, the

calipers set to 0.00.

IN/MM- toggles from decimal inches with fractions to millimeter.

ZERO- sets display to 0.00 at any position

Auto shut off- turns power off automatically after 30 minutes and

retains calibration. After 4 hours turns off completely.


Battery Replacement and Trouble Shooting:



For questions, comments, and more information go to: www.wixey.com

Problem

Possible
Cause

Solution

Flashing Digits

Low
Voltage

Replace Battery

No Display

Low
Voltage

Replace Battery

No Display

Bad
Contact

Clean Battery

Erratic or
Frozen Display

Internal
Error

Remove Battery
Wait 1 Minute
and Replace

Advertising