Alto-Shaam COMPITHERM 2020ESG User Manual

Page 10

Advertising
background image

COMBITOUCH

TM

ESG SERIES • GAS INSTALLATION MANUAL • 8.

10

•10

ES

G

21-11/16"

(550mm)

5-3/16"

(131mm)

42-1/16" (1068mm)

40-1/8"

(1018mm)

37" (939mm)

34-5/16"

(871mm)

Water Drain

(Bottom)

5" (125mm)

5-9/16" (140mm)

40-1/8" (1019mm)

33-7/8" (860mm)

44-15/16" (1141mm)

25"

(635mm)

7-1/2"

(191mm)

6-1/4" (159mm)

B

C

D

2-15/16"

(74mm)

2" (50mm)

47-5/16" (1201mm)

2-3/8" (60mm)

10-9/16

"

(267mm)

19-3/8" (492mm)

5-11/16" (144mm)

4-1/2" (114mm)

A = UNTREATED WATER
B = TREATED WATER
C = ELECTRICAL
D = GAS

A

Steam

Vent

(Top)

58-3/16" (1478mm)

15-3/16"

(385mm)

Water Drain

(Back Side)

DIMENSIONS:

H x W x D

EXTERIOR:

44-15/16” x 42-1/16” x 37” (1141mm x 1068mm x 939mm)

EXTERIOR WITH RECESSED DOOR:

44-15/16” x 46-1/16” x 37” (1141mm x 1170mm x 939mm)

INTERIOR:

27-3/8” x 17-3/8” x 26-13/16” (695mm x 440mm x 680mm)

GAS REQUIREMENTS

(

TYPE MUST BE SPECIFIED ON ORDER

)

INSTALLATION REQUIREMENTS

CONNECTED ENERGY LOAD:

68,000 Btu / hr

Oven must be installed level.
Hood installation is required.
Water supply shut-off valve and back-flow preventer.
Alternate burner orifice is required for installation sites at

elevations of 2,000 feet (610m) above sea level.

HOOK-UP: 3/4”

NPT

MINIMUM CONNECTED PRESSURE:

5.5” W.C. (Natural Gas)
9” W.C. (Propane)

MAXIMUM CONNECTED PRESSURE:

14” W.C.

ELECTRICAL

(DEDICATED CIRCUIT REQUIRED)

1010ESG

1010ESG / sk

VOLTAGE PHASE

CYCLE/HZ

AWG

AMPS

kW

AMPS

kW

110 – 120

1

50/60

NEMA 5-20P, 20A, 125V Plug, AWG 12

9.2

1.05

13.7

1.57

OTHER VOLTAGES AVAILABLE:

Range 200 – 415V – 1 or 3 ph, 50 or 60 Hz

WEIGHT

CAPACITY

NET

300 lb est (136 kg)

FULL-SIZE PANS: 20” x 12” x 2-1/2”

Ten (10)

Nine (9)

SHIP

457 lb

(207 kg)

GN 1/1: 530 x 325 x 65mm

Ten (10)

Nine (9)

CRATE DIMENSIONS: (L x W x H) EST

HALF-SIZE SHEET PANS:*

18” x 13” x 1”

Ten (10)

Nine (9)

45” x 53” x 48”

ON WIRE SHELVES ONLY

(1143 x 1346 x 1219mm)

120 lb (54 kg) MAXIMUM

VOLUME MAXIMUM: 75 quarts (95 liters)

*ADDITIONAL WIRE SHELVES REQUIRED FOR MAXIMUM CAPACITY

WATER REQUIREMENTS

WATER QUALITY MINIMUM STANDARDS

TWO (2) COLD WATER INLETS - DRINKING QUALITY

ONE (1) TREATED WATER INLET: 3/4” NPT*
ONE (1) UNTREATED WATER INLET: 3/4” NPT*
LINE PRESSURE: 30 to 90 psi 2.8 to 6.2 bar

WATER DRAIN: 1-1/2” CONNECTION WITH A 2” MINIMUM

AIR GAP INSTALLED AS CLOSE TO THE OVEN AS POSSIBLE

USING A WATER SUPPLY NOT MEETING ALTO-SHAAM’S MINIMUM
WATER QUALITY STANDARDS WILL VOID THIS WARRANTY.
It is the responsibility of the purchaser to ensure that incoming water supply is
compliant with the specifi cations listed through adequate treatment measures.
Installation of the CombiGuard

TM

Water Filtration System is recommended, but

this system may not address all water quality issues present.

CLEARANCE REQUIREMENTS

Contaminant

Free Chlorine

Hardness

Chloride

pH

Alkalinity

Silica

Total Dissolved Solids (tds)

Inlet Water Requirements (

untreated water

)

Less than 0.1 ppm (mg/L)

Less than 3 gpg (52 ppm)

Less than 30 ppm (mg/L)

7.0 to 8.5

Less than 50 ppm (mg/L)

Less than 12 ppm (mg/L)

Less than 60 ppm

LEFT 6” (152mm)

RECOMMENDED SERVICE ACCESS: 18” (457mm)

20” (508mm)

FROM HEAT PRODUCING EQUIPMENT

RIGHT 4” (102mm) TOP: 20” (508mm)

FOR AIR MOVEMENT

BACK 4” (102mm) BOTTOM: 5-1/8” (130mm)

FOR LEGS

COUNTER-TOP INSTALLATIONS MUST MAINTAIN

4” (102mm)

MINIMUM

CLEARANCE FROM COUNTER SURFACE

* Can manifold off of

one 3/4” line.

Advertising
This manual is related to the following products: