ESG SERIES • GAS INSTALLATION MANUAL • 22.

INSTALLATION

1-1/2” (41mm)
diameter connection
required

Condensate Pan
Clean Out

The oven must discharge through an indirect waste pipe by means of an air gap. The drain fitting is supplied
with a 1-1/2-inch (41mm) NPT thread.

A union is required. Install a 1-1/2-inch (41mm) diameter connection, drain line and clamp into place.
The drain line must always be a positive gradient
away from the Combitherm oven and not more
than 12-inches (305mm) before an air gap.

NOTE:

In the U.S.A., this equipment is to be

installed to comply with the Basic Plumbing
Code of the Building Offi cials and Code
Administrators International, Inc. [BOCA],
and the Food Service Sanitation Manual of
the Food & Drug Administration [FDA].

If several units are to be connected to one drain
pipe, the dimensions of the pipe must be sufficient
to allow an unobstructed water drain system.

WATER VALVE

WATER DRAINAGE

NOTE:

THE SHUT-OFF VALVE
MUST BE IN THE OPEN POSITION
WHEN THE OVEN IS BEING USED.

1-1/2" (41mm) diameter NPT
at back of oven

WASTE PIPE

1-1/2" to 2" minimum diameter

(c. 38mm to 51mm)

2" (51mm)

Air Gap

1-1/2” (41mm) diameter
NPT at back of oven

WASTE PIPE

1-1/2” to 2” minimum diameter

(c. 38mm to 51mm)

2” (51mm)

Air Gap

SHUT-OFF VALVE SHOWN
IN THE OFF POSITION