INSTALLATION

ELECTRICAL

An electrical wiring diagram is located behind the

control panel on the left side of the oven. This appliance

must be branch circuit protected with proper ampacities,

in accordance with the wiring diagram.

Wire size for the main incoming power to the

unit must match the minimum size listed in the

specifications applicable to the specific oven model.

For supply connections, locate the wire size posted

on the label located on the electrical control box

cover, behind the service panel.

Before operating the oven, check all cable connections

in the electrical connection area for tightness since

connections can loosen during transport.

NOTE:

After both water and electrical

connections have been completed, operate

the oven in any cooking mode for a period

of 15 minutes and recheck the main power

connections at the terminal block to make

certain they remain tight.

380-415V:

To prevent an electrical shock hazard between the

appliance and other appliances or metal parts in close

vicinity, an equalization-bonding stud is provided.

An equalization bonding lead must be connected

to this stud and the other appliances / metal parts

to provide sufficient protection against potential

difference. The terminal is marked with the following

symbol

.

NOTE:

Refer to local codes for connecting

appliance to an electrical circuit that is
protected by an external GFCI outlet.

MODEL

VOLTAGE

PHASE

CIRCUIT

AWG

6•10esG AND

6•10esG/SK

110-120

1

20 A

2 WIRE

7•14esG AND

7•14esG/SK

110-120

1

20 A

2 WIRE

10•10esG AND

10•10esG/SK

110-120

1

20 A

2 WIRE

10•20esG AND

10•20esG/SK

110-120

1

20 A

2 WIRE

12•18esG AND

12•18esG/SK

110-120

1

20 A

2 WIRE

20•20esG AND

20•20esG/SK

110-120

208-240

208-240

1

1

3

30 A

2 WIRE

3 WIRE

4 WIRE

OTHER VOLTAGES AVAILABLE:

Range 200 — 415V, 1 or 3 ph, 50 or 60 Hz

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code ANSI/
NFPA No. 70. In Canada, all electrical
connections are to be made in
accordance with CSA C22.1, Canadian
Electrical Code Part 1 or local codes.

D A N G E R

ENSURE POWER SOURCE
MATCHES VOLTAGE STAMPED
ON APPLIANCE NAMEPLATE.

D A N G E R

ELECTRICAL GROUNDING
INSTRUCTIONS:

This appliance is equipped with a
three-pronged (grounding) plug for
your protection against shock hazard
and should be plugged directly into
a properly grounded three-prong
receptacle. Do not cut or remove the
grounding prong from this plug.

D A N G E R

AVERTISSEMENT:

Directives

pour la prise de courant électrique Cet
appareil est muni d'une fi che à trios
branches (prise de Courant) afi n de
vous proéger des chocs et doit être
branché Directemet dans un receptacle
adequate de prise do courant À trios
branches. II ne faut pas couper ou
enlever une banche De cette fi che.

Advertising
This manual is related to the following products: