Electrical Connections

Figure 3 Electrical Connections
Power supply
:
Two supply voltage alternatives:
-

+L

12 volt supply input (11 VDC - 20 VDC)

-

+H

24 volt supply input (18 VDC - 30 VDC)

-

GND

common ground for power supply

Average current consumption is 100 mA (+ current output, max. 20 mA)

Analog outputs:
-

0

common for both analog outputs

-

V

voltage output (default 0-1 V, on request 0-2 V, 0-2.5 V or 0-5V)

-

mA

current output (default 4-20 mA, on request 0-20 mA)

Serial interface:
The interface is a 5 V (TTL) level full duplex serial port.

-

GND

signal ground (same potential as the supply GND)

-

TX

data transmitted by the CO

2

module (low state corresponding mark)

-

RX

data received by the CO

2

module (low state corresponding mark)

Leave other serial interface pins unconnected.

Probe wires: If the CO

2

module is ordered with a separate probe cable, solder the wires

to the component board according to colors shown in Figure 3.