Vaisala TCI101 NiteStar User Manual

Page 21

Advertising
background image

TROUBLESHOOTING CONTINUED…
4. Enter the proper calibration number or re-calibrate as described
in the Calibration section of your manual. Remember even if
working properly, the DMI will not count unless a calibration num-
ber has been entered.

5. If after step #3 the instrument does not power up, the problem
may be in the instrument and it should be returned for service.

Instrument is operational but does not count.

If the Nitestar has power and is operational but does not count,
the trouble is most likely installation or sensor related.

1. Check your connector as described earlier. If no power, check
for a loose connection or blown fuse. Always wear safety goggles
and protective clothing.

2. If you do have power to the DMI you may have a bad sensor.
To verify a bad sensor do the following:

A. Make sure the DMI has a Calibration Number.
If not, you can enter a fictitious number such as 900.

B. Set the DMI up just like you expect to drive away and have it
count (press Run/Hold key, etc.)

C. At the terminal block remove the green wire that comes from
the Nitestar.

D. Tap the green wire to the black wire several times. The black
wire should be ground. The instrument should count, it will reg-
ister a random number, but it should register a number. If it reg-
isters a number, most likely everything from the terminal block up
to the DMI is working, and the sensor may be defective.

E. If the DMI did not register a count, the wiring harness or the
DMI may be faulty.

If you have any questions, please call for Technical support at
(724) 438-8750. If you return your DMI always include a note
with your Name, Address (Both street and P.O Box) and a tele-
phone number so that we can contact you if necessary.

38

LIMITED WARRANTY

The Nu-Metrics Nitestar instruments are covered by a one year

limited warranty on parts and labor against defects in materials
and workmanship. Sensors, targets, cables, connectors, brack-
ets and other hardware is warranted for ninety (90) days.

Nu-Metrics, Inc. warrants each new instrument manufactured by

it to be free from defective material and workmanship and agrees
to remedy any such defect or to furnish a new part in exchange
for any part of any unit of its manufacture which under normal
installation, use and service discloses such defect, provided the
unit is returned to our factory or authorized service agent, intact,
for examination, with all transportation charges prepaid.

This warranty does not extend to any of our products which have

been subjected to misuse, neglect, accident, incorrect wiring not
our own, improper installation or to use in violation of instructions
furnished by us, nor extended to units which have been repaired
or altered outside of our factory or authorized service agent.

Any part of a unit approved for remedy or exchange hereunder

will be remedied or exchanged by the authorized agent or our fac-
tory sales division without charge to the owner.

This warrant is in lieu of all other warranties expressed or

implied and no representative or person is authorized to assume
for us any other liability in connection with the sale of our prod-
ucts. Nu-Metrics, Inc. reserves the right to make improvements
in the product specifications at any time without notice.

Questions concerning this warranty or any Nu-Metrics, Inc. prod-

uct should be directed to either the Sales or Service Department
at: (724) 438-8750

39

Advertising
This manual is related to the following products: