6 module 6 - s, Etpoint, Larm – Red Lion PAXCK User Manual

Page 18: Arameters, Parameter menu, On-off t-out latch

Advertising
background image

18

ª

«

SETPOINT ACTION

This parameter determines the mode for output deactivation as shown below.

Output activation is controlled by the SETPOINT ON parameter setting.

The

and

selections are not available when Setpoint is assigned

to

.

PARAMETER MENU

ª

«

SETPOINT SELECT

Select the Setpoint (alarm) output to be programmed. This provides access to

the parameters for that particular Setpoint. The “ ” in the following parameter
displays, reflects the chosen Setpoint number (1 thru 4). After the chosen
Setpoint is programmed, the display returns to

. Select the next

Setpoint to be programmed and continue this sequence for each Setpoint. Select

to exit the module.

and

apply to Quad Setpoint cards only.

ª

«

OUTPUT LOGIC

Normal Output Logic (

) turns the output “on” when activated and “off”

when deactivated. Reverse Output Logic (

) turns the output “off” when

activated and “on” when deactivated.

ª

«

SETPOINT ASSIGNMENT

Select the meter display to which the Setpoint is assigned: Timer (

),

Cycle Counter (

), Real-Time Clock Date display (

) or Real-Time

Clock Time display (

). (The

and

selections only appear if a

Real-Time Clock option card is installed.)

By selecting

, the Setpoint is not assigned to a specific display.

However, the output can still be activated (set) and deactivated (reset) by
various “events”. Such events include the Timer starting or stopping, or another
Setpoint output turning On or Off. The output can also be set and reset through
a User Input function or through serial communications.

This parameter determines when the Setpoint output will activate. Output

activation can occur at a specific Setpoint Value (

) or can be triggered by

various “events”, as shown in the parameter list. Such events include the Timer
starting (

) or stopping (

), or by the action (event) that causes

another Setpoint output to turn On or Off. When programmed for an event, the
Setpoint must not be used as the Setpoint On event for another Setpoint.

Selecting

displays a sub-menu where the Setpoint value is entered. The

Setpoint value is based on the meter display to which the Setpoint is assigned
(

). When assigned to the Timer or Cycle Counter, the Setpoint value is

entered in the same format as the assigned display. When assigned to the Real-
Time Clock Date Display (

), the date value is entered in month.day.year

format (

). When assigned to the Real-Time Clock Time Display (

),

the Setpoint value is always entered in

format (Hours-Minutes with

AM/PM selection). In Setpoint One-shot mode (See Daily On Occurrence), the
One-shot Setpoint is enabled (armed) by scrolling the AM/PM digit until the 2nd
digit decimal point is lit.

SETPOINT OFF

ª

«

ª

«

to

Based on “Setpoint Off” Setting

After “Time-Out Value” Elapses

At Reset (Manual or Automatic)

On-Off Output Mode

Timed Output Mode

Latched Output Mode

OUTPUT DEACTIVATES

DESCRIPTION

ON-OFF

t-OUt

LAtCH

DISPLAY

SETPOINT ON

ª

«

The Setpoint Off parameter only appears when the Setpoint Action (

)

is programmed for On-Off Output mode (

). In this mode, this parameter

determines when the Setpoint output will deactivate. Output deactivation can
occur at a specific Setpoint Off Value (

) or can be triggered by various

“events”, as shown in the parameter list. Such events include the Timer starting
(

) or stopping (

), or by the action (event) that causes another

Setpoint output to turn On or Off. When programmed for an event, the Setpoint
must not be used as the Setpoint Off event for another Setpoint.

Selecting

will display a sub-menu where the Setpoint Off value is

entered. The Setpoint Off value is based on the meter display to which the
Setpoint is assigned (

). When assigned to the Timer or Cycle Counter, the

value is entered in the same format as the assigned display. When assigned to
the Real-Time Clock Date Display (

), the date value is entered in

month.day.year format (

). When assigned to the Real-Time Clock Time

Display (

), the value is always entered in

format (Hours-Minutes

with AM/PM selection).

ª

«

to

= Setpoint Number 1 thru 4

This module can only be accessed if a Setpoint Card is installed.

6.6 MODULE 6 - S

ETPOINT

(A

LARM

) P

ARAMETERS

(

)

Module 6 is the programming module for the Setpoint (Alarm) Output

Parameters. This programming module can only be accessed if a Setpoint card
is installed. Depending on the card installed, there will be two or four Setpoint
outputs available. The Setpoint Assignment and Setpoint Action parameters
determine the applicable Setpoint features, and dictate which subsequent
parameters will appear for the Setpoint being programmed.

This section of the bulletin replaces the bulletin shipped with the Dual and

Quad Setpoint plug-in cards. Discard the separate bulletin when using Setpoint
plug-in cards with the PAXCK and PAXTM.