Nstalling the, Eter, Etting the – Red Lion PAXCK User Manual

Page 5: Umpers

Advertising
background image

5

Installation

The meter meets NEMA 4X/IP65 requirements for indoor use when properly

installed. The meter is intended to be mounted into an enclosed panel. Prepare
the panel cutout to the dimensions shown. Remove the panel latch from the

meter. Slide the panel gasket over the

rear of the meter to the back of the

bezel. The meter should be

installed fully assembled.

Insert the meter into the

panel cutout.

While holding the meter in place, push the panel latch over the rear of the

meter so that the tabs of the panel latch engage in the slots on the case. The
panel latch should be engaged in the farthest forward slot possible. To achieve
a proper seal, tighten the latch screws evenly until the meter is snug in the panel
(Torque to approximately 7 in-lbs [79N-cm]). Do not over-tighten the screws.

Installation Environment

The meter should be installed in a location that does not exceed the operating

temperature and provides good air circulation. Placing the meter near devices
that generate excessive heat should be avoided.

The bezel should only be cleaned with a soft cloth and neutral soap product.

Do NOT use solvents. Continuous exposure to direct sunlight may accelerate
the aging process of the bezel.

Do not use tools of any kind (screwdrivers, pens, pencils, etc.) to operate the

keypad of the meter.

PANEL CUT-OUT

1.0 I

NSTALLING THE

M

ETER

2.0 S

ETTING THE

J

UMPERS

To access the jumpers, remove the meter base from the meter case by firmly

squeezing and pulling back on the side rear finger tabs. This should lower the
latch below the case slot (which is located just in front of the finger tabs). It is
recommended to release the latch on one side, then start the other side latch.

Warning: Exposed line voltage exists on the circuit boards. Remove

all power to the meter and load circuits before accessing inside of
the meter.

Timer Input Logic Jumper

One jumper is used for the logic state of both timer inputs. Select the proper

position to match the input being used.

User Input Logic Jumper

One jumper is used for the logic state of all user inputs. If the user inputs are

not used, it is not necessary to check or move this jumper.

JUMPER SELECTIONS

The

indicates factory setting.

Main

Circuit

Board

USER

INPUT

JUMPER

SRC

SNK

TIMER

INPUT

JUMPER

SRC

SNK

Advertising