Alto-Shaam 1767-SK/III User Manual

Page 11

Advertising
background image

PG

. 10

767-SK/III, 1767-SK/III, 2800-SK/III

INSTALLATION

/

OPERATION

/

SERVICE MANUAL

The appliance must be installed by a qualified

service technician. The oven must be properly

grounded in accordance with the National

Electrical Code and applicable local codes.
Plug the unit into a properly grounded receptacle

ONLY, positioning the unit so that the plug is

easily accessible in case of an emergency. Arcing

will occur when connecting or disconnecting the

unit unless all controls are in the “

OFF

” position.

Proper receptacle or outlet configuration or

permanent wiring for this unit must be installed

by a licensed electrician in accordance with

applicable local electrical codes.

230V:

To prevent an electrical shock hazard between

the appliance and other appliances or metal

parts in close vicinity, an equalization-bonding

stud is provided. An equalization bonding lead

must be connected to this stud and the other

appliances / metal parts to provide sufficient

protection against potential difference.

The terminal is marked with the following

symbol.

NOTE:

The appliance must be connected to an

electrical circuit that is protected by an

external GFCI outlet.

E L E C T R I C A L C O N N E C T I O N

I N S T A L L A T I O N

E L E C T R I C A L - 7 6 7 - S K / I I I

VOLTAGE

PHASE

CYCLE

/

HZ

AMPS

kW

CORD

&

PLUG

208-240 (

UL

) 1

60

16.0

3.85

NO CORD

at 208

1

60

15.5

3.21

&

PLUG

at 240

1

60

17.8

4.27

230

1

50

16.0

3.68

CEE

7/7

220-230V

PLUG

E L E C T R I C A L - 1 7 6 7 - S K / I I I

VOLTAGE

PHASE

CYCLE

/

HZ

AMPS

kW

CORD

&

PLUG

208-240 (

UL

) 1

60

32.0

7.70

NO CORD

at 208

1

60

30.9

6.43

&

PLUG

at 240

1

60

35.6

8.55

230

1

50

34.1

7.86

NO CORD

&

PLUG

D A N G E R

ENSURE POWER SOURCE

MATCHES VOLTAGE STAMPED

ON APPLIANCE NAMEPLATE.

D A N G E R

To avoid electrical shock, this
appliance MUST be adequately
grounded in accordance with local
electrical codes or, in the absence of
local codes, with the current edition
of the National Electrical Code
ANSI/NFPA No. 70. In Canada, all
electrical connections are to be
made in according with CSA C22.1,
Canadian Electrical Code Part 1 or
local codes.

ELECTRICAL - 2800-SK/III

VOLTAGE

PHASE

CYCLE

/

HZ

AMPS

kW

CORD

&

PLUG

208

1

60

43.1

8.96

CORD

,

NO PLUG

208

3

60

27

8.96

NO CORD

&

PLUG

230

1

50

37.1

8.54

NO CORD

&

PLUG

D A N G E R

ELECTRICAL CONNECTIONS MUST

BE MADE BY A QUALIFIED SERVICE

TECHNICIAN IN ACCORDANCE WITH

APPLICABLE ELECTRICAL CODES.

1P

H

3P

H