5 changing the installation position, 6 tightening torques – ARI Armaturen CONA Universal ANSI 300 EN User Manual

Page 14

Advertising
background image

Page 14

Rev. 0040808001 0611

Operating and installation instructions

CONA

®

Universal / CONA

®

Connector

7.5 Changing the installation position

a) Bimetallic steam trap BR604 / Thermostatic steam trap BR622
(refer to Fig. 1 page 6 bis Fig. 2 page 6)
Installation in any position, except cap (pos. 6) upside down :
- Release pressure from the steam trap (shut-off inlet; with back pressure also shut-off

behind the steam trap)

- Loosen the two hexagon screws (pos. 27)
- Change installation position of the steam trap, take care of the position of the gaskets

(pos. 11, 17)

- Tighten the two hexagon screws (pos.27) (refer to item 7.6).

b) Thermodynamic steam traps BR642
(refer to Fig. 2 page 6)
Installation in any position:
- Release pressure from the steam trap (shut-off inlet; with back pressure also shut-off

behind the steam trap)

- Loosen the two hexagon screws (pos. 27)
- Change installation position of the steam trap, take care of the position of the gaskets

(pos. 11, 17)

- Tighten the two hexagon screws (pos.27) (refer to item 7.6).

For Fig.643 is no change of the installation position possible.
The steam trap must always be installed with strainer plug (pos. 7) downwards.

c) Ball float steam traps BR628
(refer to Fig. 5 page 6)
No change of the installation position possible.
The steam trap must always be installed with plug (pos. 50) downwards.

7.6 Tightening torques

(refer to Fig. 1 page 6 - Fig. 11 page 12)

pos.

Torque (Nm)

12

Theaded bush

10

13

Safety nut

70

14

Banjo bolt

70

15

Fitting

90

16

Stem guiding

90

27

Hexagon screws

20