8.0 Troubleshooting

In the event of malfunction or faulty operating performance check that the installation and
adjustment work has been carried out and completed in accordance with these Operating
Instructions.

If malfunctions cannot be eliminate with the help of the following table
9.0 Troubleshooting table”, the supplier or manufacturer should be consulted.

9.0 Troubleshooting table

-

ATTENTION !
- It is essential that the safety regulations are observed when identifying faults.

ATTENTION !
- refer to item 10.0 and 11.0 prio
r to dismantling and repair work!
- refer to item 6.0 befo
re restarting the plant!

Fault

Possible cause

Corrective measures

No flow

Installed in wrong flow direction

Fit valve in direction of flow arrow

Flange covers not removed

Remove flange covers

At BR628:
Ball float (pos. 24.16) defective

Change steam trap

Little flow

Piping system clogged

Check piping system

At BR682:
Strainer clogged (pos. 2)

Clean strainer; refer to item 7.4

Changed upstream pressure or back
pressure operating conditions

Correct selection acc. to flow diagram

Wrong installation position

Note installation position;
refer to item 5.3!
Correct installation position;
refer to item 7.5

No closure, or internal
leakage

Shut-off valve clogged

Clean shut-off valve; refer to item 7.1

Shut-off valve worn

Replace shut-off valve; refer to item 7.1

Shot-off valve operated above safe oper-
ating pressure

Observe operating limits as per data
sheet

Controller worn out

Change steam trap; refer to item 7.4

Diaphragm capsule worn out

Change steam trap; refer to item 7.4

External leakage

Shut-off valve not properly tightened

Tighten; refer to item 7.6

Flat gasket (pos. 5, 10) defective

Replace sealing;
refer to item 7.2 and 7.3