ARI Armaturen CONA Universal ANSI 300 EN User Manual

Page 5

Advertising
background image

Rev. 0040808001 0611

Page 5

Operating and installation instructions

CONA

®

Universal / CONA

®

Connector

c) System connector with stop function at inlet BR683
(refer to Fig. 8 page 7)
The valve is based on an integrated, Low-maintenance stop valves with gland seal
(also as low-maintenance bellows seal stop valve with approval acc. to TA-Luft ):
(refer to Fig. 10 page 11 - Fig. 11 page 12)

- safety back-sealing mechanism

with stuffing box: stem (pos. 11) / screw fitting (pos. 15)
with bellows seal: stem (pos. 11) / stem guide (pos. 16)

This valve is recommended specially for the CODI as steam trap.

Valve position:

OPEN - Safety back-sealing mechanism effective when valve fully open.

SHUT - Valve plug (pos. 4) / chamfer at seat (Pos 3) seal effective.

d) System connector with stop function at inlet and outlet BR684
(refer to Fig. 9 page 7)
same as c) but with two stop valves
Easy replacement of the connected steam traps by shutting-off
of inlet and outlet.

ATTENTION !
Do not use shut-off valves for OPEN-SHUT function to throttle volume flow.