4.3 Technical data
Operating Voltage
U
B
24V 50-60Hz
-20% +10%
115V 50-60Hz
-20% +10%
230V 50-60Hz
-20% +10%
Operating current
I
B
150 mA
40 mA
20 mA
Output positioning signal
Y
u
0(2) ... 10V DC (working resistance > 1000
)
Output positioning signal
Y
i
0(4) ... 20mA DC (working resistance < 800
)
Potentiometer input
R
p
0....1000
(Tol. +30/-50%)
Type of enclosure
IP40 (clamps IP20)
Ambient temperature
-20....+70 °C
4.4 Dimensions
Fig. 1