4.3 Technical data

Operating Voltage

U

B

24V 50-60Hz

-20% +10%

115V 50-60Hz

-20% +10%

230V 50-60Hz

-20% +10%

Operating current

I

B

150 mA

40 mA

20 mA

Output positioning signal

Y

u

0(2) ... 10V DC (working resistance > 1000

 )

Output positioning signal

Y

i

0(4) ... 20mA DC (working resistance < 800

 )

Potentiometer input

R

p

0....1000

 (Tol. +30/-50%)

Type of enclosure

IP40 (clamps IP20)

Ambient temperature

-20....+70 °C

4.4 Dimensions

Fig. 1