Hydraulic fan system controller – hfs-3-12v, Connection options – High Country Tek HFS-3 User Manual

Page 14

Advertising
background image

Hydraulic Fan System Controller – HFS-3-12v

14

NOTE:-

The ‘Emergency Fan STOP’ configuration shown above assumes that the controller is

being used in Inverted mode i.e. :

10% PWM = fan full on, 90%PWM = fan full off.

Closing the relay will force the input to 12V supply voltage and the fan will be controlled to fully
OFF and will remain in this state until the relay is released.

If the NON-Inverted mode is selected, the relay should be connected to 0V to achieve fan OFF
when relay energized.

0VDC

BLUE

GREEN

YELLOW

RED

Rubber
gasket

+12VDC ( +10 to +14V max )

Engine Control

Unit ( ECU )

+ PWM

output

PWM 0V

output

Proportional Valve Coil

0VDC

BLUE

YELLOW

RED

Rubber
gasket

+12VDC ( +10 to +14V max )

+ PWM

output

PWM 0V

output

Proportional Valve Coil

GREEN

Engine Control

Unit ( ECU )

Emergency Fan
STOP relay
configuration.

NC

NO

Connection Options:

Advertising