3.5 CONFIG

3.5.1 Lock

Keypad

If you do not want the user to be able to select screen formats or cameras, set this option to
YES. To change screen format you now have to enter menu, enter password and change
the screen format in the Format menu.

3.5.2 Termination

Select here whether you want each camera input to be terminated with 75 Ohms. The
default is termination ON.

• Use

left and right to move the cursor

• Use

up and down to select termination. A solid block indicates that termination is

ON (75 Ohms). A dash indicates that termination is OFF (high impedance)

• Use

DEFAULT to default the termination settings to all ON.

3.5.3 Password

The default password (111100) may be changed in this menu.

3.5.4 Transmit

Config

This menu option allows the whole menu configuration to be transmitted via the RS485
output. If you are using the Vi-SA1 configuration manager software, it is not necessary to
use this option as the software requests the configuration automatically.

3.5.5

Restore Factory Settings

Set this option to Yes if you want to default all settings including screen formats to the
factory defaults.