1 mains input, 2 connections to dome, 3 connections to dvr – Videoswitch CMOR D3 Dome User Manual

Page 10: Mains input, Connections to dome, Connections to dvr, Cmor dome

Advertising
background image

CMOR Dome

Videoswitch Page

6

Vc607a.doc

2.2.1 Mains

Input

Connect the incoming fused mains power to the terminal block marked MAINS INPUT
making sure the LIVE, NEUTRAL and EARTH wires are correctly connected.

Identification MAINS

INPUT

Live

Live (brown) 240Vac 50Hz

Neutral

Neutral (blue) 240Vac 50Hz

Earth Earth

(Yellow/Green)

2.2.2 Connections to dome

Connect the umbilical cable from the dome to the terminal block marked DOME.

Identification DOME

CAM2

White Coax signal (dual camera version only)

GND

White Coax screen (dual camera version only)

CAM1 Black

Coax

signal

GND Black

Coax

screen

RS485 (A)

WHITE

RS485 (B)

ORANGE

+24V RED

0V

BLACK and Cable screen

2.2.3 Connections to DVR

Connections to the DVR or other recording/control equipment should be made to the
terminal block marked DVR/KBD/MONITOR.

Identification DVR/KBD/MONITOR

CAM2*

GND

Camera input (dual camera version only)

CAM1*

GND

Camera input

RS485 (A)

RS485 (A) or (+) dome output

RS485 (B)

RS485 (B) or (-) dome output

Spare Not

connection

GND RS485

ground

1

*Note that the video connection(s) made be made either using the BNC connectors or
the screw terminals, whichever is more convenient.