Use the following chart to determine when the hook must be replaced. Replacement of the hook

is necessary if any of the previous page problems are found or the maximum dimensions on the

charts that follow are reached.

Chain Inspection

Inspect chain before each use. Between regular inspections visually check on a daily basis the following:

• Clean chain before inspection using a non-caustic/non-acid solvent

• Lubrication of the chain may be necessary if it binds up or is noisy

• Chain feeds smoothly into and from the hoist and does not emit cracking noise when hoisting a load

• Visually examine link by link for any nicks, gouges, weld splatter, corrosion, or distorted links pay close

attention to chain’s contact points, which may show excessive wear.

• Test hoist with load and observe operation of chain over load sheaves.

Size

Standard K

(mm) (in)

Max K

(mm) (in)

0.75 ton

26 (1.02”)

28.5 (1.12”)

1.5 ton

32.5 (1.27”)

35.5 (1.39”)

3 ton

37 (1.45”)

40.5 (1.59”)

Size

Standard H

(mm) (in)

Min H

(mm) (in)

Standard T

(mm) (in)

Min T

(mm) (in)

.75 ton

21.5 (.84”)

19.3 (.75”)

13 (.51”)

11.7 (.46)

1.5 ton

28.8 (1.13”) 25.9 (1.01”)

17 (.66”)

15.3 (.60”)

3 ton

42.9 (1.68”) 39.5 (1.55”)

25 (.98”)

22.5 (.88”)