-14-

HONEYWELL L8148 J

WITH MILLIVOLT GAS VALVE

BOILERMATE

®

JUNCTION BOX

(PLACE A WIRE NUT OVER

EACH WIRE NOT USED)

ORANGE

ORANGE

BLUE

BLUE

VIOLET

VIOLET

WHITE

BLACK

BOILERMATE

®

CIRCULATOR

L1 L2

L8148J

C1 C2

L1 L2

B1 B2 B3

B

R

T W TV

TP Z

HI

LIMIT

HONEYWELL L8148 J

WITH 24 VOLT GAS VALVE

BOILERMATE

®

JUNCTION BOX

(PLACE A WIRE NUT OVER

EACH WIRE NOT USED)

ORANGE

ORANGE

BLUE

BLUE

VIOLET

VIOLET

WHITE

BLACK

BOILERMATE

®

CIRCULATOR

L1 L2

L8148J

C1 C2

L1 L2

B1 B2 B3

B

R

T W TV

TP Z

HI

LIMIT

WHITE - RODGERS 8J48 A

WITH 24 VOLT GAS VALVE

8J48A

BOILERMATE™

JUNCTION BOX

ORANGE

ORANGE

BLUE

BLUE

VIOLET

VIOLET

WHITE

BLACK

(PLACE A WIRE NUT OVER

EACH WIRE NOT USED)

B1

B2

TV W

T

TP Z

B

C1

C2

L2

L1

B3

WHITE - RODGERS 8J48A

WITH 24 VOLT GAS VALVE

8J48A

BOILERMATE

®

JUNCTION BOX

ORANGE

ORANGE

BLUE

BLUE

VIOLET

VIOLET

WHITE

BLACK

(PLACE A WIRE NUT OVER

EACH WIRE NOT USED)

B1

B2

TV W

T

TP Z

B

C1

C2

L2

L1

B3