Time-out timer, Transverter, Dsp rx equalizer – Kenwood TS-590S User Manual

Page 63

Advertising
background image

55

12 OPERATOR CONVENIENCES

RX MONITOR

RX monitor temporarily disables the squelch function
to monitor the current frequency activities.

To use the RX Monitor function, first assign the
function to a PF key (either on the front panel or the
microphone).

1 Press

[MENU], then press [Q-M.IN]/ [Q-MR] or

turn the MULTI/CH control to select Menu No.
79 ~ 86.

2 Press

[M.IN]/ [SCAN (SG.SEL)] to select “203”.

3 Press [MENU] to exit Menu mode.

4 Press the assigned [PF] key.

• While

pressing

[PF], the speaker unmutes.

TIME-OUT TIMER

The Time-out Timer limits the time of each
transmission. It is also useful to prevent a long
accidental transmission.
1 Press

[MENU], then press [Q-M.IN]/ [Q-MR] or

turn the MULTI/CH control to access Menu No. 49.

2 Press

[M.IN]/ [SCAN (SG.SEL)] to select “oFF”,

“3”, “5”, “10”, “20”, or “30” minutes.

3 Press [MENU] to exit Menu mode.

TRANSVERTER

If you have a transverter that converts the TS-590S
operating frequencies to other frequencies, you can
use this TS-590S transceiver as a transverter exciter.
Consult the instruction manual that came with the
transverter for interfacing to the TS-590S transceiver.

FREQUENCY DISPLAY

1 Connect the transverter to the ANT 1, ANT 2, RX

ANT, or DRV connector of the TS-590S.

2 Select the exciter operating frequency on the

transceiver.
• The transverter will use this frequency as the

reference for converting frequencies.

3 Press

[MENU], then press [Q-M.IN]/ [Q-MR] or

turn the MULTI/CH control to access Menu No. 50.

4 Press

[M.IN]/ [SCAN (SG.SEL)] to select “1”.

• The output power is automatically set to the

lowest power for that frequency (default). Refer
to “TX POWER” {below}.

5 Press [MENU] to exit Menu mode.

6 Press

[ENT], then set the target converting

frequency using the numeric keys.

7 Press

[ENT] to complete the entry.

• The transceiver displays the target transverter

frequency instead of the actual operating
frequency.

No.

Function

Remark

202

VOICE3

The lower meter when
transmitting

203

MONITOR

Mic [PF4] default

204

TX TUNE

205

DATA SEND

The input voice from
the data terminal is
transmitted

206

DOWN

Mic [DWN] default

207

UP

Mic [UP] default

208

EMERGENCY

Emergency frequency
call (K type only)

OFF

No function

Note:

Assigned key functions may not work, depending on the

setting.

[AGC SEL] can be used in modes other than FM mode,

and can set a step level of the chosen AGC time constant
(FAST/ SLOW).

[TONE SEL] can also be used in FM mode while TONE or

CTCSS is ON,

DSP RX EQUALIZER

EQUALIZING RECEIVING AUDIO

Use Menu No. 31 to change the receiver frequency
responses of the target signal. You can select one
from 8 different receiver profiles including the default
flat response. Selecting any of the following items
from the Menu causes “

” to appear on the

display.

Off (oFF):

Slightly attenuates (1 kHz or higher audio
frequencies).

High boost 1 (hb1):

Emphasizes higher audio frequencies.

High boost 2 (hb2):

Emphasizes higher audio frequencies but lower
audio frequency attenuation is less than High
boost1 (hb1).

Formant pass (FP):

Improves clarity by suppressing audio frequencies
outside the normal voice frequency range.

Bass boost 1 (bb1):

Emphasizes lower audio frequencies.

Bass boost 2 (bb2):

Emphasizes lower audio frequencies but higher
audio frequency attenuation is less than Bass
boost1 (bb1).

Flat (FLAT):

The flat frequency response.

User (U):

Reserved for the ARCP software. Off is
programmed at the factory as a default.

Advertising