26

7.2.3.2 Connection of the 24Vac power
supply line

Only for products marked UL intended for
the North American market, use a class 2 UL
listed transformer.

Power the device with an SELV type, 24Vac,
8A isolated source derived from a double
isolation UL Listed transformer specially
protected in output. Alternatively, use the
UPTIRPS120 power supply and control kit.

CN1

24Vac

24Vac

GND

a

Fig. 40

Connect the power supply cables as described in the
table below.

CONNECTION OF THE POWER SUPPLY LINE

Colour

Terminals

Power supply 24Vac
Defined by the installer

24Vac

Defined by the installer

24Vac

Yellow/Green

GND

Tab. 5

7.2.3.3 Connection of the 120/230Vac power
supply line

To connect the power supply line use the
appropriate junction-box (UPTjbUL). For
further information, refer to the product
use and installation manual.

CN1

N

L

GND

a

Fig. 41

Connect the power supply cables as described in the
table below.

CONNECTION OF THE POWER SUPPLY LINE

Colour

Terminals

Power supply 230Vac
Blue

N (Neutral)

Brown

L (Phase)

Yellow/Green

GND

Power supply 120Vac
Blue

N (Neutral)

Brown

L (Phase)

Yellow/Green

GND

Tab. 6