4 connection of the ethernet cable – Videotec ULISSE NETCAM User Manual

Page 29

Advertising
background image

Instruc

tions manual - English - EN

27

7.2.3.4 Connection of the alarm inputs, of
the twilight switch and of the relays

The installation is type TNV-1, do not
connect it to SELV circuits.

In order to reduce the risk of fire, only use
cable sizes greater than or equal to 26AWG
(0.13mm²).

All signal cables must be grouped together
by means of a strap.

O1 C1 O2 C2

V

V

Fig. 42

Relay contact connection.

AL4

AL3

AL2

AL1

AGND

Fig. 43

Alarm connection.

CONNECTION OF THE ALARM INPUTS, OF THE
TWILIGHT SWITCH AND OF THE RELAYS

Terminals

Description

O1-C1 and
O2-C2

Clean output contacts, can be activated by
alarm or by user control

AL1, AL2,
AL3, AL4 and
AGND

Self powered alarm inputs referring to AGND

Tab. 7

Connect the twilight switch to the AGND
and AL1 terminals. AL1 is the default alarm
contact for the light sensitive switch.

7.2.4 Connection of the ethernet cable

Connect the ethernet cable to the connector.

Ethernet

Fig. 44