Pre_card_string property (kb), Post_card_string property (kb) – MagTek USB MagnePrint Swipe Reader with Encryption User Manual

Page 46

Advertising
background image

USB MagnePrint Swipe Reader with Encryption

38

Example Get ACTIVE_KEYMAP property Response (Hex):

Result Code Data Len

Prp Value

00 01

00


PRE_CARD_STRING PROPERTY (KB)

Property ID:

18 (0x12)

Property Type:

String

Length:

0 – 7 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

The default value is no string with a length of zero.

Description:

The value is an ASCII string that represents the device’s pre card string. This
string can be 0 – 7 bytes long. This string is sent prior to all other card data.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.


Example Set PRE_CARD_STRING property Request (Hex):

Cmd Num

Data Len

Prp ID

Prp Value

01

04

12

31 32 33


Example Set PRE_CARD_STRING property Response (Hex):

Result Code Data Len

Data

00 00


Example Get PRE_CARD_STRING property Request (Hex):

Cmd Num

Data Len

Prp ID

00 01

12

Example Get PRE_CARD_STRING property Response (Hex):

Result Code Data Len

Prp Value

00

03

31 32 33


POST_CARD_STRING PROPERTY (KB)

Property ID:

19 (0x13)

Property Type:

String

Length:

0 – 7 bytes

Get Property:

Yes

Set Property:

Yes

Default Value:

The default value is no string with a length of zero.

Description:

The value is an ASCII string that represents the device’s post card string.
This string can be 0 – 7 bytes long. This string is sent after all other card data.

This property is stored in non-volatile memory, so it will persist when the unit
is power cycled. When this property is changed, the unit must be reset (see
Command Number 2) or power cycled to have these changes take effect.

Advertising