Support for excella on pc side, How to install excella – MagTek Excella Windows API99875313 User Manual

Page 14

Advertising
background image

Excella Windows API Specifications


6

SUPPORT FOR EXCELLA ON PC SIDE:

To support Excella on the PC side, a template INF file provided by Microsoft was modified to
install the RNDIS drivers. There are two driver files provided by Microsoft:

rndismp.sys
(export driver and is linked to usb8023.sys)
usb8023.sys (For an RNDIS USB Device)

When usb8023.sys is loaded the system automatically loads rndismp.sys.

Windows XP has built in support for RNDIS. Windows 2000 does not have RNDIS drivers.
MagTek supplies RNDIS driver for Windows 2000.


HOW TO INSTALL EXCELLA

The hardware installation requirements are specified in Excella, MICR Check Reader and Dual-
Sided Scanner,
P/N 99875310. Appendix A of this manual describes the installation process for
Excella Demo program.


HOW TO COMMUNICATE WITH EXCELLA USING INTERNET EXPLORER

Excella can be accessed from an Internet Web browser using the IP address of the device. An
example in using the IP address of the Excella device to obtain device capabilities information is
followed.

Assuming the Excella device has IP address 192.168.10.100, type the following line in the
address box of the Web browser. Internet Explorer is used in this example.:

192.168.10.100\Excella?DeviceInformation=DeviceCapabilities

Press the Enter key, and the Excella responds with the results shown below: