ImageSafe Windows API Specifications
96
Fmt 76xx:
'T' [transit] 'A' [acct #] 'C' [check #] 'M' [raw data]
• [transit]:
- all characters in the field
- remove dashes and spaces
• [acct #]:
- maximum of xx characters; when xx=00 all characters are sent
- remove dashes and spaces
• [check #]:
- all characters in the field- remove dashes and spaces
• [raw data]: - translate MICR symbols to t,o,a,d