Section 6. Keys Received From Device


55

SECTION = DocInfo

The DocInfo section includes keys that report on various attributes of the check document and
information on the MICR data read from the check.

DocUnits
This key specifies the units of measurement used to report on check document dimensions (see the
DocWidth and DocHeight keys below).

Values

Value Description

ENGLISH

Dimensions in thousands of an inch

METRIC

Dimensions in millimeters

DocWidth
This key specifies the width of the check document based on the scanned image.

Values

Value Description

numeric value

Width dimension of scanned document

DocHeight
This key specifies the height of the check document based on the scanned image.

Values

Value Description

numeric value

Height dimension of scanned document

MICRFont
This key specifies the MICR font detected and read from the check.

Values

Value Description

E13B

E13B font was detected on the check read

CMC7

CMC7 font was detected on the check read

Note

The parsed MICR fields below only apply to U.S. checks with E13B font.

CMC7 Checks are not parsed, and only the raw MICR line is reported.

MICRRaw
This key specifies the unformatted (as-is) MICR data read from the check.

Values

Value Description

string

Unformatted MICR data

MICRAcct
This key specifies the account number MICR field read from the check.

Values

Value Description

string

Account number MICR field