Timing for back sensor and card present – MagTek MT-215 TTL SINGLE HEAD, 3-TRACK User Manual

Page 14

Advertising
background image

MT-215 TTL Single Head, 3-Track, Insertion Reader


8

TIMING FOR BACK SENSOR AND CARD PRESENT

Figure 2-3 shows the timing for the Back Sensor and the Card Present signals.

TIME OF INSERTION

TIME OF WITHDRAWAL



HEAD OUTPUT



















Figure 2-3. Timing for Back Sensor and Card Present signals


While it is possible for the Card Reader to read data on either the insertion or withdrawal stroke,
it should be noted that card reading is most reliable during the card withdrawal stroke. For this
reason MagTek recommends that customer’s software should be designed to emphasize data
capture during the card withdrawal stroke. For the most reliable operation: Read the card upon
insertion, when the card present goes high, check for errors, if no errors, output the data, start
sentinel first, after the card is withdrawn. If an error is detected, clear the stored data and read
the card on withdrawal, if no errors, output the data, start sentinel first, otherwise output an error
indication or a try again message.

SIGNAL

CARD PRESENT
AT CONNECTOR

INTERNAL CARD
PRESENT

BACK SENSOR
AT CONNECTOR

ACTIVE DATA

MOST RELIABLE
ACTIVE DATA

NOTE 1

NOTE 1

NOTE 1

NOTE 1:

Time out of the internal card present signal occurs approximately 150 ms
after the last strobe transition. The internal card present signal becomes
active when the movement of an encoded magnetic stripe past the read
head generates a signal. The back sensor and internal card present are
gated together to reduce the dwell time needed before the read-on-
withdrawal can be initiated.

NOT TO SCALE